Question posted - May 21 to May 27, 2012:

What tests should be run to determine if an existing concrete bridge pier needs rehabilitation or repair before cleaning and coating?


Selected Answers

From Jeremi Day of Allphaz Inspection Services on May 22, 2012:
     There are several non-destructive tests (NDT) that can be used to evaluate the strength of hardened concrete. Two of the most common NDT methods are the Schmidt rebound hammer and the Windsor probe, both of which measure the surface hardness of concrete as a quick indicator of relative compressive strength. The rebound hammer test (ASTM C 805) measures the rebound of a spring-loaded plunger pressed against a concrete surface. The harder the surface, the greater the extent of the rebound, which correlates to relatively greater strength. In the Windsor probe test (ASTM C 803), a powder-actuated gun drives hardened alloy probes into the concrete. The exposed length of the probe is measured, then related by a calibration table to the concrete's compressive strength. The results of these tests can be influenced by a variety of factors, including surface smoothness, type and hardness of aggregates, age and moisture condition of the concrete, and the degree of carbonation at the surface. Therefore, it's important that results be compared with those from cored or cast specimens, and interpreted by NDT specialists who understand the limitations of the tests.

From Otto Drozd of J. Mori Painting, Inc on May 23, 2012:
     Conduct a visual inspection of the surface to be coated to determine if any of the following are present: voids, bugholes, pop-outs, cracks, joints, spalls, fins/slivers, levelness , efflorescence, soundness, oil, grease,wetness/dryness, carbonation, chemical, ASR/AAR, transition areas below/above grade, age of concrete, blisters/other.  Evaluate  the severity of the damage detected and determine if it is critical that rehabilitation work be done.


Please sign in to submit your answer this question

   

Tagged categories: Bridges; Concrete; Concrete repair; Site/field testing


Current PSF Question | Submit a PSF Question | Full PSF Archive

 
 
 

Technology Publishing Co., 1501 Reedsdale Street, Suite 2008, Pittsburgh, PA 15233

TEL 1-412-431-8300  • FAX  1-412-431-5428  •  EMAIL webmaster@durabilityanddesign.com


The Technology Publishing Network

Durability + Design PaintSquare the Journal of Protective Coatings & Linings Paint BidTracker

 

© Copyright 2012-2019, Technology Publishing Co., All rights reserved